2016 SAW Grant Storm Sewer CCTV Investigation - City of Center Line RFP-0170-0382-032916

City of Center Line » RFP-0170-0382-032916

The information below is a summary of solicitation number RFP-0170-0382-032916 posted by City of Center Line.  As a reminder, this solicitation is closed and responses are no longer being accepted.

2016 SAW Grant Storm Sewer CCTV Investigation

Date Issued: 03/30/2016

Deadline: 04/12/2016  prior to 10:00 AM   E.D.T.

Requisition Number:

Delivery Point: City of Center Line

Delivery Date: Spring 2016

Type of Purchase: Term: Unspecified

Construction Related: No

Type of Response Allowed: Hard Copy Only

Issuing Agency: City of Center Line

Using Department: Department of Public Works

Special Notices: All or None Award
Bid Bond Required
Contractors License Required
Insurance Required
License Required
Maintenance Bond Required
No Brand Name Specified
Payment Bond Required
Performance Bond Required
Performance Bond/Guarantee Required
Surety Bond Required
Training Required
Warranty Information Required

ACCEPTING VENDOR QUESTIONS:

Due Date: 4/5/2016 3:00:00 PM E.D.T.

Primary Contact Name: Mr. Gary McKinney

Title: DPW Director

Email: gmckinney@centerline.gov

SUMMARY OF SPECIFICATIONS:

The City of Center Line will receive sealed bids until 10:00 am, local time on Tuesday, April 12, 2016, at the offices of the City Manager/City Clerk, City of Center Line, 7070 East Ten Mile Road, Center Line, Michigan 48015, at which time and place all bids will be publicly opened and read aloud. DESCRIPTION OF WORK The approximate quantities involved in this work are as follows: Cleaning and CCTV Investigation of Catch Basin Leads 25,000 LF Cleaning and CCTV Investigation of 6” - 12" Storm Sewers 55,000 LF Cleaning and CCTV Investigation of 15” - 21" Storm Sewers 27,000 LF Cleaning and CCTV Investigation of 24” - 36" Storm Sewers 21,000 LF Cleaning and CCTV Investigation of 42" – 48” Storm Sewers 5,100 LF CCTV Investigation of 54” Storm Sewers 2,000 LF CCTV Investigation of 60” Storm Sewers 1,400 LF CCTV Investigation of 66” Storm Sewers 1,400 LF CCTV Investigation of 72” Storm Sewers (Man Entry) 1,700 LF CCTV Investigation of 78” Storm Sewers (Man Entry) 3,500 LF CCTV Investigation of 84” Storm Sewers (Man Entry) 2,100 LF together with related work, video, and inspection reports. PRE-QUALIFICATION All CCTV Inspections shall be performed by a NASSCO Pipeline Assessment and Certification Program (PACP©) certified operator. All inspection reports shall be produced using (C.C.T.V.) inspection software provided by a NASSCO PACP© certified vendor. Formatting and layout, i.e., observations and defect codes, shall be NASSCO PACP© standard. DUE TO FILE SIZE LIMITATIONS ON MITN SYSTEM. PLEASE USE THE FOLLOWING LINK TO ACCESS RFP-0170-0382-032916 SPECIFICATIONS: https://www.aewinc.com/DownloadWeb/predownload.aspx?qs=LR82FPL2G ZR6BC4LTYCJM6H69KVKXTNX39BCXW5QT2X8MDWJMYRJ3YFTZEUH84AV6FCBAD99S LFFUWYG28THNCMKYBXNAS56GFUPA4GXVTP42T3NAPATN9R5CBG7C72U6DTV7HXFZ HZGRA246EDNKSTQRPR4KNHQLLJ9SR5Y5EAQ4PND3DQ4AFUBGSJATAAPZ2ZUP34BN 8W3EQ7K9D3VS6SWHWLRTGZMV3BRQBPC8LJCP8BTD2XYD3RBM989CBDPHUDTP3DUR IF YOU ARE UNABLE TO DOWNLOAD THE DOCUMENT VIA THE AFOREMENTIONED LINK, PLEASE CONTACT PATRICK MARCUS OF AEW AT PMARCUS@AEWINC.COM OR 586-726-1234. 

Get Automatic Notification and More


REGISTER

  • Real-time notification of solicitations, addenda and awards
  • Advance notice of term contract expirations
  • Full customer service support
  • Opportunities matched to your business
  • Access opportunities from all member agencies in one location